BNT-2000AP specification sheet

Current Specials & Promotions
Product specification information

Specifications for BNT-2000AP

PowerCom Line-Interactive UPS

BNT-2000AP Gallery image 1 [Size: 383 (W) x 310 (H)]   BNT-2000AP Gallery image 2 [Size: 249 (W) x 351 (H)]  
Powercom® Line-Interactive 2000VA, AVR, RS232& UTP, 1xSurge, 4xBackup, Fax/Modem, Recharge: 6-Hrs (90%), 80-90min

UPS 220V / 230V uninterrupted power supplies

Powercom

Out of Stock
This product is no longer available for purchase. This information is for reference purposes only.
Click here to browse for similar products and for great alternatives!

Quality Protection for Small Servers, and Workstations & PCs.

Features :

  • Line interactive design
  • Boost and buck AVR (Auto voltage regulation)
  • Fully digitized microprocessor controlled
  • Energy saving function (UPS green mode)
  • 50/60Hz frequency auto sensing and selection
  • Smart RS-232 communication port
  • Advanced battery management (ABM technology)
  • Tel/Modem internet surge suppression
  • Automatically charging when UPS off
  • History record of power failure events
  • Back up, on-line, battery status, power status display by software
  • Schedule shutdown & reboot
© 2026 Respective owners and brand holders. This table has been carefully researched and generated by ComXpert International CC (//www.comx-computers.co.za), however, errors and omissions may occur. Only references to South Africa apply. All products are sourced in South Africa from the official suppliers and the warranty is that of the local supplier. E&OE. This table and our site's content may be used on condition that this notice and link remains intact and unaltered.
Specifications and features
Product Code BNT-2000APspacer
MODEL          
CAPACITY Capacity

1000VA

1200VA

1500VA

2000VA

OUTPUT Voltage (on battery) Simulated sine wave at 100V / 110V / 115V / 120V or 220V / 230V / 240V +/- 5%
Frequency (on battery) 50 or 60 Hz +/-1Hz
Voltage Regulation( AVR) AVR automatically increase output voltage 15% above input voltage if -9% to -25% of nominal.
AVR decrease output voltage 13% below input voltage if +9% to +25% of nominal
Transfer Time 2 / 4 milliseconds, including detection time
INPUT Voltage 100V / 110V / 115V / 120V or 220V / 230V / 240V +/- 25% at line input
Frequency 50 or 60 Hz +/- 10% (auto sensing)
PROTECTION
& FILTERING
Spike Protection 480 Joules, 2ms
Unit Input Fuse or circuit breaker for overload & short circuit protection
Overload Protection UPS automatic power off if overload exceeds 110% of
nominal at 60 seconds and 130% at 3 seconds
10 Base-T Cable Port  
Short Circuit UPS output cut off immediately or input fuse protection
BATTERY Type Sealed, maintenance-free lead acid batteries with 3-6 years typical lifetime
Typical Recharge Time 6 hours (to 90% of full capacity)
Back-up Time
(a PC with 15" monitor)
60 - 70 mins 65 - 75 mins 70 - 80 mins 80 - 90 mins
Protection Auto discharge protection
PHYSICAL Net Weight Kg (lbs) 13.4 (28.6) 13.4 (28.6) 15.9 (35.0) 15.9 (35.0)
Shipping Weight Kg (Ibs) 14.8 (32.6) 14.8 (32.6) 17.3 (38.0) 17.3 (38.0)
Dimension WxDxH (mm) 382 x 130 x 192
(15.0" x 5.1" x 7.5")
Input Inlet IEC 320 power inlet
Receptacles NEMA 5-15R(115V) / IEC 320 female appliance coupler (220V)
INTERFACE RS232  
ALARM Battery Back-up Slow beeping sound (about 0.47 Hz)
Battery Low Rapid beeping sound (about 1.824 Hz)
Overload Continuously beeping sound
ENVIRONMENT Ambient Operation 3,500 meters max, elevation. 0-95% humidity non-condensing, 0-40 ¢J
Audible Noise <40dBA (1 meter from surface)
Storage Condition 15,000 meter max. elevation