BR1300MI specification sheet

Current Specials & Promotions
Product specification information

Specifications for BR1300MI

APC BR1300MI Back UPS Pro BR 1300VA UPS

BR1300MI Gallery image 1 [Size: 389 (W) x 553 (H)]  
APC BR1300MI Back UPS Pro BR 1300VA, 8 Outlets, AVR, LCD Interface

UPS 220V / 230V uninterrupted power supplies

APC (American Power Convertion)

Out of Stock
This product is no longer available for purchase. This information is for reference purposes only.
Click here to browse for similar products and for great alternatives!

Overview:

High Performance Computer and Electronics UPS for Premium Power Protection

Features:

Audible alarms
Provides notification of changing utility power and UPS power conditions

Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.

Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance

Battery replacement without tools
Enables fast battery replacement, lowering Mean Time to Repair (MTTR).

Battery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment

Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).

Cold-start capable
Provides temporary battery power when the utility power is out.

Dataline surge protection
Provides protection of connected equipment from power surges on the data lines.

Disconnected battery notification
Warns when a battery is not available to provide backup power.

Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced

LCD graphics display
Text and mimic diagrams that display modes of operation, system parameters and alarms.

Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

USB connectivity
Provides management of the UPS via a USB port (not available on all models).

User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)

Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

Surge only outlets
Protect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.

Battery and surge protected outlets
Back up and protect your hardware and data during power outages, surges and spikes.

Dataline surge protection
Provides protection of connected equipment from power surges on the data lines.

Boost Automatic Voltage Regulation (AVR)
Preserves battery life and maximizes runtime by correcting low voltages without discharging the battery.

LCD Status Display
Provides key UPS status at a glance. Multiple status indicators with load and battery bar graphs.

Green mode
Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.

Battery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment

Simple battery replacement
Increases UPS availability by allowing quick, easy battery replacement.

Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse. (Not available on Wall Tap SKUs)

Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).

Green mode
Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.

Transformer-block spaced outlets
Protect equipment with input transformer blocks without blocking access to other receptacles.

Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance

Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.

Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.

Cold-start capable
Provides temporary battery power when the utility power is out.

Customizable voltage-transfer points
Adjust the voltage points (widen or tighten the range) where your UPS transfers to battery to maximize useful battery life and protect sensitive electronics.

Customizable voltage sensitivity
Toggle between pre-determined voltage-transfer points depending on your power quality (high, medium or low sensitivity), maximizing useful battery life and protecting sensitive electronics.

Audible alarms
Provides notification of changing utility power and UPS power conditions

Disconnected battery notification
Warns when a battery is not available to provide backup power.

LCD Status Display
Provides key UPS status at a glance. Multiple status indicators with load and battery bar graphs.

USB connection
Use your PC to access additional power protection and management features for your UPS via a USB Port.
 

Specifications:

©2026 Respective owners and brand holders. This table has been carefully researched and generated by ComXpert International CC (//www.comx-computers.co.za), however, errors and omissions may occur. Only references to South Africa apply. All products are sourced in South Africa from the official suppliers and the warranty is that of the local supplier. E&OE. This table and our site's content may be used on condition that this notice and link remains intact and unaltered.
Specificationsspacer
Product CodeBR1300MIspacer
Output
Output power capacity 780Watts / 1.3kVA
Max Configurable Power (Watts) 780Watts / 1.3kVA
Nominal Output Voltage 230V
Output Frequency (sync to mains) 50/60 Hz +/-1 Hz
Topology Line Interactive
Output Connections (2) IEC 320 C13 (Surge Protection)
(6) IEC 320 C13 (Battery Backup)
Input
Nominal Input Voltage 230V
Input frequency 50/60 Hz +/- 3 Hz (auto sensing)
Input Connections IEC-320 C14
Input voltage range for main operations 176 - 294V
Maximum Input Current 10.0A
Batteries & Runtime
Battery type Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
Typical recharge time 16hour(s)
Expected Battery Life (years) 3 - 5
RBC Quantity 1
Battery Volt-Amp-Hour Capacity 177
Communications & Management
Interface Port(s) USB
Control panel Multi-function LCD status and control console
Audible Alarm Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm
Surge Protection and Filtering
Surge energy rating 509Joules
Data Line Protection RJ45 10/100/1000 Base-T Ethernet protection
Filtering Full time multi-pole noise filtering :10% of IEEE surge let-through : zero clamping response time: instantaneous
Physical
Maximum Height 100MM, 10.0CM
Maximum Width 250MM, 25.0CM
Maximum Depth 382MM, 38.2CM
Net Weight 10.2KG
Shipping weight 11.85KG
Shipping Height 330MM, 33.0CM
Shipping Width 485MM, 48.5CM
Shipping Depth 225MM, 22.5CM
Color Black
Master Carton Units 1
Master Carton Weight 12.7
SCC Codes 1073130434690 3
Environmental
Operating Temperature 0 - 40 °C
Operating Relative Humidity 0 - 95 (non-condensing) %
Operating Elevation 0-3000meters
Storage Temperature -15 - 45 °C
Storage Relative Humidity 0 - 95 (non-condensing) %
Storage Elevation 0-15000meters
Audible noise at 1 meter from surface of unit 45.0dBA
Online thermal dissipation 21.5BTU/hr
Conformance
Approvals A-tick, C-tick, CE, EAC, GS Mark, RCM, TISI
Sustainable Offer Status
RoHS Compliant
REACH REACH: Contains SVHCs