Overview:
Features:
Battery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment
Surge only outlets
Protect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.
Battery and surge protected outlets
Back up and protect your hardware and data during power outages, surges and spikes .
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
LED status display
Quickly understand unit and power status with visual indicators.
Audible alarms
Provides notification of changing utility power and UPS power conditions
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Specifications:
| ©2026 Respective owners and brand holders. This table has been carefully researched and generated by ComXpert International CC (//www.comx-computers.co.za), however, errors and omissions may occur. Only references to South Africa apply. All products are sourced in South Africa from the official suppliers and the warranty is that of the local supplier. E&OE. This table and our site's content may be used on condition that this notice and link remains intact and unaltered. | |
Specifications![]() | |
| Product Code | BX950MI![]() |
| Output | |
| Max Configurable Power (Watts) | 480 Watts / 950VA |
| Output Frequency (sync to mains) | 50/60 Hz +/- 1 Hz Sync to mains |
| Topology | Line interactive |
| Waveform type | Stepped approximation to a sinewave |
| Transfer Time | 6 ms typical : 10 ms maximum |
| Input | |
| Input frequency | 50/60 Hz +/- 5 Hz Auto-sensing |
| Input voltage range for main operations | 140 - 300V |
| Number of Power Cords | 1 |
| Input Power Factor at Full Load | 0.54 |
| Batteries & Runtime | |
| Battery type | Lead-acid battery |
| Typical recharge time | 8hour(s) |
| Replacement Battery | RBC17 |
| Expected Battery Life (years) | 3 - 5 |
| Runtime | View Runtime Graph |
| View Runtime Chart | |
| Efficiency | View Efficiency Graph |
| Communications & Management | |
| Control panel | LED Status display with on line : on battery |
| Audible Alarm | Alarm when on battery : distinctive low battery alarm |
| Surge Protection and Filtering | |
| Surge energy rating | 273Joules |
| Data Line Protection | RJ45 10/100/1000 Base-T Ethernet protection |
| Physical | |
| Maximum Height | 160MM, 16.0CM |
| Maximum Width | 120MM, 12.0CM |
| Maximum Depth | 355MM, 35.5CM |
| Net Weight | 6.1KG |
| Shipping weight | 6.6KG |
| Shipping Height | 250MM, 25.0CM |
| Shipping Width | 197MM, 19.7CM |
| Shipping Depth | 430MM, 43.0CM |
| Color | Black |
| SCC Codes | 10731304410802 |
| Environmental | |
| Operating Temperature | 0 - 40 °C |
| Operating Relative Humidity | 0 - 95 (Non-condensing) % |
| Operating Elevation | 0 - 3000meters |
| Storage Temperature | -15 - 40 °C |
| Storage Relative Humidity | 0 - 95 (Non-condensing) % |
| Storage Elevation | 0 - 3000meters |
| Audible noise at 1 meter from surface of unit | 40.0dBA |
| Protection Class | IP20 |
| Conformance | |
| Approvals | CB, CE, EAC, EN/IEC 62040-1, EN/IEC 62040-2 |
| Equipment protection policy | Lifetime : 50000 euros |
Sold by ComX Computers