Gate Hub
UA-Hub-Gate
The Ubiquiti UniFi Access Gate Hub provides advanced gate access management, supporting smooth integration with Access readers and Intercom systems. Designed for both residential and commercial settings, it allows centralized control and monitoring of gates and side doors.
The UA-Hub-Gate simplifies gate management with multiple networking and relay options. It supports one gate and one side door, offering real-time status monitoring and emergency handling. Powered via PoE++, it ensures efficient energy delivery while providing DIN-Rail mounting for easy installation. With five Gigabit networking ports and four PoE outputs, it delivers high-speed connectivity and reliable operation for secure access control systems.
Connectivity and Power
Door and Gate Management
Installation and Integration
Performance and Reliability
| ©2026 Respective owners and brand holders. This table has been carefully researched and generated by ComXpert International CC (//www.comx-computers.co.za), however, errors and omissions may occur. Only references to South Africa apply. All products are sourced in South Africa from the official suppliers and the warranty is that of the local supplier. E&OE. This table and our site's content may be used on condition that this notice and link remains intact and unaltered. | |
Specifications![]() | |
| Product Code | UA-HUB-GATE![]() |
| Overview | |
| Dimensions | 175 x 126 x 26 mm |
| (6.9 x 5 x 1") | |
| UniFi Application Suite | |
| Access | Yes |
| Supported Doors | 1 gate, 1 side door |
| Input Terminals | (1) Gate exit request |
| (1) Gate position | |
| (1) Side door exit request | |
| (1) Side door position | |
| (1) Emergency | |
| Power Method | PoE++ |
| UL 294 Power-limited Class 2 PSU | |
| UL 60950-1/62368-1 LPS/PS2 PSU | |
| NDAA Compliant | Yes |
| UL 294 Level | Destructive attack: Level I |
| Line security: Level I | |
| Endurance: Level I | |
| Standby power: Level I | |
| Mechanical | |
| Weight | 460 g (1 lb) |
| Enclosure Material | Polycarbonate |
| Mounting | DIN-rail (Included) |
| Hardware | |
| Digital Input | Gate exit request, gate position, side door exit request, side door position, emergency |
| Dry Output Relay | (2) Operator: rated 30V DC, up to 1A |
| (1) Aux: rated 30V DC, up to 1A | |
| Powered Output Relay | Side door lock: 12V DC, up to 1A |
| Indoor and Outdoor Use | Indoor only: device itself |
| Outdoor: with waterproof junction box | |
| Ambient Operating Temperature | -30 to 60degrees C |
| (-22 to 140degrees F) | |
| Ambient Operating Humidity | 5 to 90% noncondensing |
| Networking Interface | (5) 10/100/1000 Base-T |
| PoE Interface | (1) PoE++ input, 50V DC, 1A |
| (4) PoE outputs, 50V DC, 30W per port | |
| (Max 55W aggregated) | |
| Max. Power Consumption | 22W (Without PoE output) |
| 60W (With PoE output) | |
| LEDs | W/B Learn More |
| Buttons | (1) Factory-reset |
| Recommend Max. Cable Length | |
| UA-Lock-Electric (400mA) | 24 AWG length: 25 m (82 ft) |
| 22 AWG length: 42 m (138 ft) | |
| 20 AWG length: 66 m (217 ft) | |
| 18 UACC-Cable-DoorLockRelay length: 100 m (328 ft) | |
| UA-Lock-Magnetic-540kg (500mA) | 24 AWG length: 20 m (66 ft) |
| 22 AWG length: 32 m (105 ft) | |
| 20 AWG length: 51 m (167 ft) | |
| 18 UACC-Cable-DoorLockRelay length: 80 m (262 ft) | |
| UA-Lock-Magnetic-270kg (800mA) | 24 AWG length: 12 m (29 ft) |
| 22 AWG length: 20 m (66 ft) | |
| 20 AWG length: 30 m (98 ft) | |
| 18 UACC-Cable-DoorLockRelay length: 46 m (151 ft) | |
| Other locks | |
| (1A) | 24 AWG length: 9 m (30 ft) |
| 22 AWG length: 15 m (49 ft) | |
| 20 AWG length: 24 m (79 ft) | |
| 18 UACC-Cable-DoorLockRelay length: 36 m (118 ft) | |
| PoE Cabling Requirements | Cat 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site. |
| The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm² ) for patch cords , 24 AWG (0.21 mm² ) for horizontal or riser cable. | |
| UL 294 Statement | Compliance with IEEE 802.3 specifications was not verified as part of UL 294. |
| The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits. | |
| CAN/ULC-60839-11-1 Grade | Grade assignment: I |
| Certifications | CE, FCC, IC, UL 294, CAN/ULC-60839-11-1 |
| Document number, and issue date and/or revision level | UA-Hub-Gate, V01 |
| Software | |
| Management Application | Access |
Sold by ComX Computers