| ©2026 Respective owners and brand holders. This table has been carefully researched and generated by ComXpert International CC (//www.comx-computers.co.za), however, errors and omissions may occur. Only references to South Africa apply. All products are sourced in South Africa from the official suppliers and the warranty is that of the local supplier. E&OE. This table and our site's content may be used on condition that this notice and link remains intact and unaltered. | |
Specifications![]() | |
| Product Code | UPS-MER2000![]() |
| MODEL | UDC9102S |
| Phase | Single phase with ground |
| Capacity | 2000VA / 1800W |
| INPUT | |
| Rated voltage | 100/110/115/120/127VAC or 200/208/220/230/240VAC |
| Voltage range | 55-145VAC or 110-300VAC |
| Frequency range | 40Hz - 70Hz (auto detect) |
| Power factor | >=0,99 |
| Bypass voltage range high voltage point | For 200/208/220/230/240 VAC models: 230-264: setting the high voltage point in LCD from 230Vac to 264Vac (default 264Vac) For 100/110/115/120/127 VAC models: 115-132: setting the high voltage point in parameter 3 from 115Vac to 132Vac (default 132Vac) |
| Bypass voltage range low voltage point | For 200/208/220/230/240 VAC models: 170-220: setting the low voltage point in LCD from 170Vac to 220Vac (default 170Vac) For 100/110/115/120/127 VAC models: 95-110: setting the low voltage point in parameter 3 from 95Vac to 110Vac (default 95Vac) |
| ECO range | Same as the bypass |
| Generator input | Support |
| OUTPUT | |
| Phase | Single phase & Ground |
| Rated voltage | 100/110/115/120/127VAC or 200/208/220/230/240VAC |
| Power factor | 0.9 |
| Voltage regulation | +-1% |
| Frequency range(Utility. mode) | 47-53Hz(for 50Hz) or 57-63Hz(for 60Hz) |
| Frequency range(batt. mode) | 50/60Hz+-0.01Hz |
| Crest factor | 0.125694444444444 |
| THDv | <3% with linear load, <6% with non linear load |
| Waveform | Pure Sinewave |
| EFFICIENCY | |
| AC mode (full load) | >89% |
| BATTERY | |
| Voltage | 48Vdc |
| Quantity | 4pcs |
| Capacity (standard unit) | 12V/9AH |
| Backup | Long run unit depends on the capacity of external batteries |
| Recharge time to 90% | 4 hours |
| Charging current (built-in/Max) | 1A, Max 12A |
| Utility to battery: 0ms, Utility to bypass: <4ms | |
| TRANSFER TIME | |
| PROTECTION | |
| Overload AC mode | 105%-110%:UPS shuts down after 10min at battery mode or transfer to bypass when the utility is normal Ambient temp< 35 C 110%-130%:UPS shuts down after 1 min at battery mode or transfer to bypass when the utility is normal >130% UPS shuts down after 3 sec |
| Overload bat. mode | 105%-110%:UPS shuts down after 1min at battery mode or transfer to bypass when the utility is normal 35 C110% UPS shuts down after 3 sec at battery mode or transfer to bypass when the utility is normal |
| Overload bypass mode | 10A(Input breaker) 16A(Input breaker) 20A(Input breaker) |
| Short circuit | Hold whole system |
| Overheat | Line mode: Switch to bypass: Backup Mode: Shut down UPS immediately |
| Battery low | Alarm and switch off |
| EPO (optional) | Shut down UPS immediately |
| Battery | Advanced battery management |
| ALARM | |
| Audible & visual | Line failure, low battery, overload, system fault |
| DISPLAY | |
| Status LED & LCD | Line mode, backup mode, eco mode, bypass mode, low battery, bad battery, overload and UPS fault |
| Reading on the LCD | Input voltage, input frequency, output voltage, output frequency, load percentage, battery voltage |
| PHYSICAL | |
| Standard Dimension (WxHxD) | 144x209x399 |
| Model Weight (kg) | 17 |
| COMMUNICATION INT | ERFACE |
| Communication port | RS232 or USB |
| Communication slot | SNMP Card, relay card etc |
| ENVIROMENT | |
| Operating temperature | 0 C-40 C |
| Humidity | 20-90% non condensing |
| Altitude | < 1500m (derating while >1500m) |
| Noise | <50dB(at 1 meter) |
| SAFETY CONFORMAN | CE |
| IEC/EN62040-1-1, IEC/EN62040-2 | |