About this product
The APC Symmetra LX 12kVA scalable to 16kVA N+1 tower UPS SYA12K16I is a high availability, modular online double conversion power system designed for mission critical infrastructure. Buy this scalable UPS solution for reliable power protection, advanced redundancy and continuous uptime support for servers, networks and data centers in South Africa.
Overview Summary
APC Symmetra LX 12kVA Scalable to 16kVA N+1 Tower UPS is a modular, high availability power protection system designed for enterprise environments requiring continuous uptime and scalable capacity. It uses online double conversion technology to deliver clean, stable power for sensitive IT equipment including servers, networking hardware and storage systems.
The system supports N+1 redundancy, allowing additional power modules to be installed to increase reliability or expand capacity up to 16kVA. Its tower form factor and modular architecture make it suitable for data centers and enterprise server rooms where uptime is critical and maintenance needs to be minimized.
With network management capability via SNMP and integrated monitoring features, this UPS provides real-time visibility and control over power conditions. It is engineered to support business continuity with automatic bypass, hot-swappable components and scalable runtime options.
Performance tier: Enterprise grade critical infrastructure UPS
Uses: servers, data centers, network switches, storage systems, IT infrastructure backup power, telecom systems
Description
The APC Symmetra LX SYA12K16I is engineered for demanding IT environments that require uninterrupted power protection and scalable architecture. Built on a modular platform, it allows businesses to expand capacity as load requirements grow, making it suitable for evolving enterprise infrastructures.
This UPS system uses online double conversion technology to continuously regulate incoming power, ensuring consistent output free from surges, spikes or outages. Its tower design integrates seamlessly into server rooms and data centers while supporting redundant configurations for improved uptime assurance.
Designed for high availability, the system includes hot-swappable power and battery modules, enabling maintenance without downtime. It is ideal for organizations that require dependable backup power for mission critical operations.
Features
The APC Symmetra LX 12kVA scalable UPS system offers advanced enterprise level power protection features designed for reliability and scalability.
- Online double conversion technology for clean and stable power output
- Modular architecture supporting scalability up to 16kVA
- N+1 redundancy for enhanced system reliability
- Hot swappable power and battery modules for zero downtime maintenance
- SNMP network management for remote monitoring and control
- Automatic and manual bypass for maintenance and fault tolerance
- Supports enterprise IT and data center environments
Shippable with modules installed
Enables pre-installation UPS staging and testing and faster installation.
Removable input/output wiring tray
Allows quick and easy installation and maintenance of the UPS.
Modular design
Provides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules.
Configurable for N+1 internal redundancy
Provides high availabilty through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load.
Redundant Intelligence Modules
Provides higher availability to the UPS connected loads by giving redundant communication paths to critical UPS functions.
Hot-swappable intelligence modules
Ensures clean, uninterrupted power to protected equipment during Intelligence Module replacement.
Hot-swappable power modules
Ensures clean, uninterrupted power to protected equipment during Power Module replacement.
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Power Modules connected in parallel
Enhances availability by allowing immediate, seamless recovery from isolated module failures.
Battery modules connected in parallel
Delivers higher availability through redundant batteries.
Automatic internal bypass
Supplies utility power to the connected loads in the event of a UPS overload condition or fault.
Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
Scalable power capacity
Reduces UPS over-sizing costs today by allowing quick upgrades later.
Scalable runtime
Allows additional run time to be quickly added as needed.
Plug-and-Play external batteries
Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.
Field-replaceable power distribution panel
Ensures compatibility with equipment that has different plug types.
Programmable frequency
Ensures compatibility with different input frequencies.
Manageable external batteries
Reduces preventative maintenance service needs by monitoring the health and status of the external batteries and their expected runtime.
Network manageable
Provides remote management of the UPS over the network.
InfraStruXure Manager Compatible
Enables centralized management via the APC InfraStruXure Manager.
LCD display
Alpha-Numeric Display which displays system parameters and alarms.
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
SmartSlot
Customize UPS capabilities with management cards.
Predictive failure notification
Provides early-warning fault analysis ensuring proactive component replacement.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Audible alarms
Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition.
User-replaceable intelligence modules
Enables simple upgrades and replacements of the Intelligence Modules.
User-replaceable power modules
Enables simple upgrades and replacements of the Power Modules.
User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Disconnected battery notification
Warns when a battery is not available to provide backup power.
Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.
Frequency and voltage regulation
Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling.
Generator compatible
Ensures clean, uninterrupted power to the loads in the event of an extended power outage
Cold-start capable
Provides temporary battery power when the utility power is out.
Resettable circuit breakers
Enables a quick recovery from overload events.
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
What's in the Box
- APC Symmetra LX 12kVA Scalable to 16kVA N+1 Tower UPS unit
- Installation guide
- User documentation
- Software CD
- Network management card
Specifications
| © 2026 Respective owners and brand holders. This table has been carefully researched and generated by ComXpert International CC (//www.comx-computers.co.za), however, errors and omissions may occur. Only references to South Africa apply. All products are sourced in South Africa from the official suppliers and the warranty is that of the local supplier. E&OE. This table and our site's content may be used on condition that this notice and link remains intact and unaltered. |
Specifications and features |
| Product Code | SYA12K16I |
| Output |
| Output Power Capacity | 8400 Watts / 12 kVA |
| Max Configurable Power | 11.2 kW / 16 kVA |
| Nominal Output Voltage | 230V |
| Output Voltage Note | Configurable for 220 : 230 or 240 nominal output voltage |
| Efficiency at Full Load | 0.9 |
| Output Voltage Distortion | Less than 5% at full load |
| Output Frequency (sync to mains) | 47 - 63 Hz |
| Other Output Voltages | 220240 |
| Crest Factor | up to 5 : 1 |
| Waveform Type | Sine wave |
| Output Connections | (1) Hard Wire 3-wire (H N + G) |
| Bypass | Internal Bypass (Automatic and Manual) |
| Input |
| Nominal Input Voltage | 230V, 400V 3PH |
| Input Frequency | 45 - 65 Hz (auto sensing) |
| Input Connections | Hard Wire 3 wire (1PH+N+G) |
| Hard Wire 5-wire (3PH + N + G) |
| Input voltage range for main operations | 155 - 276, 290 - 480 (3:1)V |
| Other Input Voltages | 220V, 240V, 380V, 415V |
| Input Total Harmonic Distortion | Less than 7% for full load |
| Batteries & Runtime |
| Battery Type | Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof |
| Included Battery Modules | 3 |
| Available Battery Slots | 1 |
| Typical recharge time | 3 hour(s) |
| Replacement Battery | SYBT5 |
| Extended Run Options | APC Symmetra LX 12kVA scalable to 16kVA N+1 Tower, 220/230/240V or 380/400/415V |
| Communications & Management |
| Interface Port(s) | DB-9 RS-232, Smart-Slot |
| Available SmartSlot Interface Quantity | 1 |
| Pre-Installed SmartSlot Cards | AP9631 |
| Control panel | Multi-function LCD status and control console |
| Audible Alarm | Audible and visible alarms prioritized by severity |
| Emergency Power Off (EPO) | Yes |
| Physical |
| Maximum Height | 937.00 mm |
| Maximum Width | 483.00 mm |
| Maximum Depth | 726.00 mm |
| Net Weight | 263.64 KG |
| Shipping Weight | 287.27 KG |
| Shipping Height | 1181.00 mm |
| Shipping Width | 599.00 mm |
| Shipping Depth | 997.00 mm |
| Colour | Black, Silver |
| Units per Pallet | 1 |
| Environmental |
| Operating Environment | 0 - 40 degreesC |
| Operating Relative Humidity | 0 - 95% |
| Operating Elevation | 0-3000 meters |
| Storage Temperature | -15 - 45 degreesC |
| Storage Relative Humidity | 0 - 95% |
| Storage Elevation | 0-4500 meters |
| Audible noise at 1 meter from surface of unit | 62.00 dBA |
| Online Thermal Dissipation | 3707.00 BTU/hr |
| Conformance |
| Regulatory Approvals | C-tick, CE, EN 50091-1, EN 50091-2, EN 55022 Class A, EN 55024, EN 60950, GOST, IEC 60950, VDE |
FAQ
What is the APC Symmetra LX 12kVA used for?
It is used for providing uninterrupted backup power to servers, data centers, and critical IT infrastructure where downtime must be avoided.
Can the system be expanded beyond 12kVA?
Yes, the modular design allows scaling up to 16kVA by adding additional power modules.
Does this UPS support redundancy?
Yes, it supports N+1 redundancy which allows continued operation even if one power module fails.
Is it suitable for small office use?
No, it is designed for enterprise and data center environments due to its size, capacity, and complexity.
Does it support remote monitoring?
Yes, it includes SNMP network management for remote monitoring and control.